Labeling an agar plate takes about ten seconds, but a poorly labeled plate can waste days of work. The standard practice is to write on the bottom of the plate, not the lid, and to include four pieces of information: the date, the sample or organism name, the medium type, and your initials. Write near the edge, never across the center where you need to see growth.
That covers the basic answer. The details matter more than most people expect, especially if you are working in a shared lab, a classroom, or a clinical setting where plates get moved, stacked, and incubated for days.
Why Do You Write On The Bottom Of An Agar Plate Instead Of The Lid?
The lid comes off. The bottom stays with the agar.
This is the single most common labeling mistake. A lid with a name on it tells you nothing once it is set down next to three other lids on a bench. The agar, the colony, and the sample are all in the bottom half. If the label is on the lid, the plate is effectively unlabeled the moment the two parts separate.
There is a second reason. Condensation forms on the inside of the lid during incubation. Marker ink on a lid smears when that moisture runs across it. The bottom stays drier.
Some labs label both the bottom and the lid as a backup. That is reasonable in a teaching lab where plates get handled by many people. In a research or clinical lab, the bottom alone is standard because the lid is treated as disposable or interchangeable.
One clarification worth making: labeling the bottom does not mean writing on the agar surface. Write on the plastic base, on the outside. Writing on the agar itself can damage the surface, introduce contamination, and the ink will diffuse into the medium.
How To Label Agar Plates: What To Write And Where On The Plate?
Write on the outer edge of the bottom half, along the rim. This keeps the center clear for observing colony growth and leaves the agar surface untouched.
The four items that belong on every plate:
- Date — the date the plate was inoculated, not the date it was poured. Use a consistent format. In US labs, month/day/year is typical.
- Sample or organism — a sample ID number, patient identifier code, environmental site code, or organism name. Whatever links the plate back to its source record.
- Medium type — nutrient agar, tryptic soy agar, MacConkey agar, blood agar, and so on. This matters because two plates from the same sample can look identical but contain different media.
- Your initials — so anyone can trace the plate back to the person who prepared or inoculated it.
Some labs add a dilution factor, a project code, or a plate replicate number. Add those if your protocol calls for it. The four above are the baseline.
Where exactly on the rim? Along the side wall of the bottom half, running parallel to the edge. Writing in a line along the curve is easier to read than writing in a circle around the whole plate, which forces the reader to rotate the plate to read it.
If you are labeling many plates at once, write the date and medium on all of them first, then add the sample ID as you inoculate each one. This reduces the chance of mixing up which plate belongs to which sample.
What Should You Use To Write On Agar Plates?
Use a permanent marker designed for lab use. Standard permanent markers work. Sharpies are widely used in teaching and research labs and hold up reasonably well under normal incubation conditions.
What does not work well:
- Ballpoint or gel pens — ink does not adhere to the plastic and smears or rubs off.
- Water-soluble markers — condensation and handling remove them quickly.
- Pencil — does not write legibly on smooth plastic.
- Adhesive labels — can peel during incubation, and some adhesives interfere with certain imaging or automated colony-counting systems.
If plates will be incubated at high humidity or for extended periods, some labs use markers rated for laboratory use that resist moisture and ethanol. These are more expensive but reduce the risk of a label becoming unreadable.
Do not write on a plate that is still warm from pouring. The plastic can flex, and the ink may not set properly. Wait until the agar has solidified and the plate has cooled.
What Are The Rules For Labeling Plates In A Clinical Or Diagnostic Lab?
Clinical labs follow written procedures that are usually more specific than general lab practice. These procedures exist because a mislabeled plate can lead to a wrong result reported for the wrong patient.
Most clinical microbiology procedures require at minimum a unique specimen identifier, the date and time of inoculation, and the initials or identifier of the person who set up the culture. Many also require the source site — urine, wound, sputum, blood — either on the plate or linked through a barcode or lab information system.
Many clinical labs use pre-printed barcode labels applied to the bottom of the plate. This reduces handwriting errors and ties the plate directly to the electronic record. When barcodes are used, handwritten information is often limited to the date and initials.
The specific requirements vary by institution and by the accrediting or regulatory framework the lab operates under. If you work in a clinical lab, follow your facility’s written procedure rather than general guidance. That procedure reflects the standards your lab is held to.
One point that applies everywhere: never label a plate with information you are not certain about. If you are unsure which sample a plate came from, discard it and start over. An unlabeled or ambiguously labeled plate is worse than no plate.
How Do You Label Plates For Different Incubation Conditions?
Incubation conditions affect how well a label holds up.
Plates incubated at 35 to 37 degrees Celsius — the standard range for many clinical and laboratory cultures — are generally kind to permanent marker ink. The main risk is condensation, which forms as the plate warms and can run across the lid and sometimes the base.
Plates incubated at higher temperatures, or for extended periods of several days to weeks, pose more of a problem. Ink can fade or smear. If your protocol involves long incubation, consider writing on a small piece of lab tape applied to the bottom rim, or use a marker rated for those conditions.
Plates stored in a refrigerator or freezer present a different issue. Cold and moisture can cause some inks to flake. Freezer-safe labels are available for plates that will be stored frozen, though most routine agar plates are not frozen.
Anaerobic jars and CO2 incubators add humidity. In those conditions, check labels before and after incubation. If a label is unreadable after incubation, the plate is of limited use.
Common Labeling Mistakes And How To Avoid Them
Most labeling errors fall into a small number of categories.
- Labeling the lid — the most frequent mistake. Always label the bottom.
- Writing across the center — obscures growth and makes colony counting harder. Keep to the rim.
- Using an ambiguous date format — 03/04/2025 could be March 4 or April 3 depending on where you trained. Pick one format and use it consistently across your lab.
- Forgetting the medium — two plates from the same sample on different media can look similar. Without the medium noted, you cannot interpret the result.
- Skipping initials — when a problem arises, no one can trace the plate back to its source.
- Writing illegibly — if no one can read it, the label has failed. Print clearly.
A useful habit: before you put a plate into the incubator, read the label back to yourself as if you were someone else picking it up. If any item is unclear, fix it now. Once the plate is incubating, you may not look at it again for a day or more.
In teaching settings, instructors often require students to label plates before inoculating, not after. This builds the habit and prevents the situation where a plate is inoculated and then set aside without a label.
Frequently Asked Questions
Should I label the lid or the bottom of an agar plate?
Label the bottom. The lid can be removed or swapped, but the bottom holds the agar and the sample, so the label stays with the plate’s contents.
What information must be on every agar plate label?
At minimum: the date of inoculation, the sample or organism identifier, the medium type, and your initials. Clinical labs may require additional identifiers per their written procedure.
Can I use a regular pen to write on agar plates?
No. Ballpoint and gel pens do not adhere well to plastic and smear easily. Use a permanent marker, ideally one rated for laboratory use if plates will be incubated in humid conditions.
Where on the plate should I write to avoid blocking colony growth?
Write along the outer rim of the bottom half, parallel to the edge. Keep the center of the plate clear so you can see and count colonies without obstruction.

